Strength class | C24, C24M | Other strength classes must be agreed upon separately (see table 1.2 of the agreements on construction timber) |
Grading class in the case of a visual grading according to DIN 4074-1 | S10 | Other grading classes must be agreed upon separately (see table 1.2 of the agreements on construction timber) |
Product standard | EN 14081-1 for non-finger-jointed KVH® structural timber EN 15497 for finger-jointed KVH® structural timber | |
Moisture content | 15% ± 3% Kiln-dried: Wood that was dried to a moisture u of ≤ 20% in a controlled process in a suitable industrial plant at a temperature of T ≥ 55 °C for at least 48 hours. | The specified moisture content is a precondition for dispensing for the most part with preservative treatment, and can also be the precondition for finger joint assembly. |
Type of cut | For a log with an ideal growth form, the pith is cut through in two-strand cutting. Upon request: Heart plank with d ≥ 40 mm is removed | For a log with an ideal growth form, the pith is cut through in two-strand cutting. | |
Wane | not acceptable | ≤ 10% of the smaller cross-section side | |
Dimensional stability of the cross-section | EN 336 Dimensional stability class 2: ≤ 10 cm = ± 1 mm; > 10 cm and ≤ 30 cm = ± 1.5 mm | The dimensional stability for the longitudinal dimensions must be agreed between the customer and the supplier. |
Knot condition | Loose knots and dead knots not acceptable. Occasional faulty knots or parts of knots up to max. 20 mm in diameter are acceptable. | DIN 4074-1 Grading class S10 | |
Knots | S 10: A ≤ 2/5 S 13: A ≤ 1/5 not exceeding 70 mm | The following applies for mechanical grading: • Knot sizes are not taken into consideration for KVH®-NSi • A ≤ 2/5 applies to KVH®-Si |
Ingrown bark | not acceptable | DIN 4074-1 Grading class S10 | Knot bark is added to the knot |
Cracks | Crack width b ≤ 3% not exceeding 6 mm | Crack width b ≤ 5% | Crack width b relating to the respective cross-section width Without limitation of the length or the number of cracks The requirements of building regulations concerning the crack depth must be observed. |
Crack depth - shrinkage cracks - cracks caused by lightning, ring shakes | Up to 1/2 Not acceptable | | Measured according to DIN 4074-1 |
Pitch pockets | Width b ≤ 5 mm | - | Corresponds to DIN 68365 quality classes 1 and 2 Without limitation of the location or the number of pitch pockets |
Discoloration | not acceptable | Blue stains: acceptable Shatter-proof brown and red stripes: up to 2/5 Brown rot, white rot: not acceptable | The requirements concerning KVH NSi correspond to those of grade S10 according to DIN 4074-1 |
Insect attack | not acceptable (DIN 68365 Quality Class 1) | Insect holes up to 2 mm diameter are acceptable | According to DIN 4074-1 |
Twisting | 1 mm per 25 mm height | Measured according to DIN 4074-1 |
Longitudinal warping | ≤ 8 mm/2 m with removed heart plank ≤ 4 mm/2m | For split‐heart cut ≤ 8 mm/2 m | Measured according to DIN 4074-1 Meets the requirements for grades S10 and S13 according to DIN 4074-1 |
Finishing of the ends | Trimmed perpendicular (by agreement) | |
Surface condition | Planed and chamfered | Levelled and chamfered | |