Monitoring and labelling

of glued solid timber (Duobalken®/Triobalken®) according to EN 14080:2013

The manufacturer shall issue a declaration of performance. Below there's an example of a declaration of performance for Duobalken®.

The highlighted text is manufacturer-specific.

Declaration of performance

No. xyz

1.

Unique identification code of the product type:

Name of product type 1

Name of product type 2

2.

Intended use:

Buildings and bridges

3.

Manufacturer:

Sample company

Street address

Postcode City

Country

4.

Legal representative:

No external legal representative

5.

System of assessment and verification of constancy of performance:

   

System 1

6.a)

Harmonised standard:

EN 14080:2013

 

Notified body:

Nr. 1234

7

Declared performance:

 

The performance of the above product types corresponds to the declared performance. The above-named supplier is solely responsible for the preparation of the declaration of performance in accordance with the EU Regulation no. 305/2011.

Signed for and on behalf of the manufacturer by:

………………………………………………………………………………………………………………………………

(Name and position)

………………………………………………………………………………………………………………………………

 (Place and date of issue)


CE conformity marking

Reference is made to the declaration of performance in the CE mark on the product, the packaging, or the delivery note.

1)

12342)

Sample company3)

 

144)

 

No xyz5)

EN 14080:20136)

Glued solid timber from spruce without preservative treatment 7)
for use in buildings and bridges8)

Mechanical properties and fire resistance as9)

Geometrical data (mm) 

160 x 240 x 12000

Strength class and characteristic density 

C 24

Species 

Spruce

Bonding strength als 
Bending strength of finger joints 

24 N/mm2

Glued joints integrity test

B

Reaction to fire

D-s2, d0

Emission of formaldehyde

E1

Durability of the bonding strength as 
Species 

Spruce

Adhesive for surface joints between slats

MUF, IGP70S

Adhesive for finger joints

PUR, I

Durability of other characteristics as 
Natural resistance against wood-destroying fungi 

5

1) CE mark according to the 93/68/EEC Directive

 

2) number of the notified body

3) name or initials of the manufacturer, not: The manufacturer`s address may be amended

4) last two digits of the year of the original inspection

5) number of the declaration of performance

6) standard number with year of publication

7) product description

8) scope of application

9) mandated characteristics