1. System, building component dimensions
Timber beam ceiling in the form of a
simply supported beam
Spacing between beams: e=62.5m
Material: KVH® structural timber, C 24
2. Characteristic action
Permanent (dead loads) gK-1.75 kN/m2
Variable (live load including lightweight partition walls qk,N = 2,80 kN/m²
ERROR: Content Element with uid "1048" and type "templavoila_pi1" has no rendering definition!
Load combinations for verifications of load-bearing capacity
No. | Combination | Combination rule | Dimensioning value | Load duration class | kmod |
---|---|---|---|---|---|
LK 1 | g | 1.35 · gk | Σqd = 2.36 kN/m² | Long | 0.60 |
LK 2 | g + p | 1.35 · gk + 1.5 · qk | Σqd = 6.56 kN/m² | Medium | 0.80 |
LK 2 is clearly decisive in this case, and this is used for further consideration.
Comparison with the results from dimensioning reference table 6.2.2
For dimensioning criterion B: erf b/h = 12/24 cm:
ERROR: Content Element with uid "1054" and type "templavoila_pi1" has no rendering definition!
ERROR: Content Element with uid "1086" and type "templavoila_pi1" has no rendering definition!
ERROR: Content Element with uid "1059" and type "templavoila_pi1" has no rendering definition!
4. Stresses - Internal forces and moments and reactions at support
Internal forces and moments per beam
(e = 62.5 cm)
ERROR: Content Element with uid "1064" and type "templavoila_pi1" has no rendering definition!
ERROR: Content Element with uid "1069" and type "templavoila_pi1" has no rendering definition!
5. Preliminary estimate
Required section modulus:
Wy,req = Md / fm,d = 10.38 · 10³/ 14.8 Wy,req = 701 cm³
ERROR: Content Element with uid "1074" and type "templavoila_pi1" has no rendering definition!
6. Verifications for the limit of load-bearing capacity state
Dimensioning value for bending stress:
σ m,y,d = Md / Wy = 10.38 / 768 · 10³
σ m,y,d = 13.5 N/mm²
Verification:
Results from dimensioning reference table 6.1 (Cross-sectional values):
für Md = 10.38 kNm erf b/h = 8/24 cm
ERROR: Content Element with uid "1079" and type "th_exttable_pi1" has no rendering definition!
Dimensioning value for shearing stress:
τ d = 1.5 · Vd / A = 1.5 · 9.23 / 192
τ d = 0.72 N/mm²
Verification:
ERROR: Content Element with uid "1075" and type "templavoila_pi1" has no rendering definition!
ERROR: Content Element with uid "1083" and type "th_exttable_pi1" has no rendering definition!
7. Verifications for the limit of serviceability state
According to DIN 1052, Section 9.2, the following three cases have to be examined each one is only shown for variable action:
a) Limitation of deflection as a result of variable loads (initial deflection without creep influences):
wQ,inst = wQ,1,inst + χ0,2 · wQ,2,inst ≤ l/300
b) Limitation of final deflection with creep influences as a result of all loads without consideration of initial deflection:
wfin – wG,inst = wG,inst (1 + kdef) + wQ,1,inst (1 + y2,1 · kdef) – wG,inst ≤ l/200
c) Limitation of deflection in the quasi-permanent dimensioning situation for guaranteeing general usability and appearance:
wfin – w0 = wG,inst (1 + kdef) + wQ,1,inst · y2,1 (1 + kdef) – w0 ≤ l/200
Calculation of deflection
E0,mean · Iy = 1.100 · 9.216 = 10.14 · 106 kNcm²
wG,fin = wG,inst (1 + kdef) = 0.58 · (1 + 0.6) = 0.928 cm
Proof of deflection
Case a) wQ,inst = 0.92 cm = l/489 < l/300
Case b) wfin – wG,inst = 0.58 (1 + 0.6) + 0.92 (1 + 0.3 · 0.6) – 0.58 = 1.43 cm = l/313 < l/200
Case c) wfin – w0 = 0.58 (1 + 0.6) + 0.92 · 0.3 (1 + 0.6) - 0 = 1.37 cm = l/329 < l/200
Simplified vibration verification
(Limitation of deflection as a result of quasi-permanent action to w = 6 mm in accordance with DIN 1052, Section 9.3):
w = wG,inst + c2 · wQ,inst = 0.58 + 0.3 · 0.92 = 0.86 cm
w = 8:6 mm > 6 mm (verification requirement not met)
Option 1:
Increase the moment of inertia / the beam width by 8.6/6 • 100 = 43%.
ERROR: Content Element with uid "1084" and type "templavoila_pi1" has no rendering definition!
Option 2
It is recommended that exact vibration verifications be calculated, which should provide more cost-effective results. Suitable verification methods can be found, for example, in "Erläuterungen zu DIN 1052:2004-08" [1] ("Commentary on DIN 1052:2004-08").
Reference moment for LK 2:
Md = Σqd · l² / 8 = 6.56 · 4.50² / 8 · 0.625
Reference lateral force for LK 2:
Vd = Σqd · l / 2 = 6.56 · 4.50 / 2 · 0.625
Modification factor for solid timber
Partial safety factor for wood
Dimensioning value for flexural strength
Dimensioning value for shear strength
Result B (with simplified vibration verification)
KVH® C24: 12/24 cm
Alternative: Duobalken®,Triobalken® C24: 14/22 cm
ERROR: Content Element with uid "1047" and type "templavoila_pi1" has no rendering definition!